Cinematography Mailing List - CML
    advanced

2024 CML Camera/Lighting TestsLight Measurements


Mole-Richardson Tener Solarspot 416

10K tungsten fresnel.

More info: Mole-Richardson


Note: brightness depends on the output mode of the light (some lights have modes that optimize brightness, others that optimize color, others that minimize fan noise...). The output mode is listed in tests where it was recorded, otherwise it is whatever mode the light was delivered in. The mode we tested may not be the mode used in the manufacture’s published specs. Use these brightness numbers to compare conditions only within this test. If you need a lamp to hit specific levels, please check with the manufacturer — or test it yourself!



Bare Fixture @ Flood, 100% power at 3 meters / 9.85 feet


Color
Setting
BrightnessCCT∆uvSSITM-30-18TLCICRI(Ra)
  lux   fc  Rf  Rg 
3200 K2610024303265 K0.00039510010010099.5
Note:bulb looks new




Measurements and Beam Patterns at 3 meters / 9.85 feet

Light is aimed at the central pipe with the green tape on it. Tape marks indicate 15º increments of beam spread: each tape mark is 7.5º from its neighbor, so the two tape marks closest to the center marker span 15º total. The next nearest ones span 30º between them, the next pair out indicate 45º, and so on. Images captured with the camera (Lumix GH5) set to 5600 K white balance, “standard” photo style, using a 7mm lens. No adjustments made in post other than resizing for the web.

ModifierBrightnessCCT∆uv
  lux   fc 
Bare Fixture @ Flood2610024303265 K0.0003
Note:bulb looks new

ModifierBrightnessCCT∆uv
  lux   fc 
Bare Fixture @ Mid5460050703322 K0.0003

ModifierBrightnessCCT∆uv
  lux   fc 
Bare Fixture @ Spot10200094703301 K0.0005


Copyright © CML. All rights reserved.